Is there anything you can suggest at this point that I could try to get this combination to work? I could see looking at the phone logs that the calls were being placed for about 30 seconds, but apparently there was too much jitter or something for it all to work correctly. Unfortunately my tests to the monitoring service resulted in the system retrying several times but they never got the signals on the other end. I thought perhaps this too might work for the alarm signals so decided to give it shot. They claim that it works fairly well for faxing as it uses a G711 codec. Then I heard about this voip service from NetTalk that lets you plug their Duo device directly into the router. That just left the phone requirement for the alarm system. One thought I had was to cut out the Uverse phone as we really didn't need it for actual talking since we all have cell phones.
![yellow light on dsc alarm panel yellow light on dsc alarm panel](https://www.fire-monitoring.com/wp-content/uploads/2015/09/DSC-Power-Series-Keypad-with-Trouble-Light.jpg)
I now have read the info that ATT has provided stating how they have made their voice service work reliably with alarm systems and it does seem to in fact work.Īll that is great except for the staggering bills I am starting to get for the Uverse service. I didn't even realize at the time that I had the alarm system setup (it was put in months after the Uverse service was added) that there were any tricky issues with alarms and voip, it all just magically worked from the start. My DSC PC1832 works reliably as far as I can tell when using the Uverse voip service. I have ATT Uverse service right now providing both internet and their voip. #8 (Loss of Date and Time on the Keypad) can be resolved yourself by following the instructions in this tech tip.I read over the FAQ of this forum and know that voip is notĬonsidered too reliable with alarm systems, but I thought I would ask to see what you guys think about my specific situation. Service Required (You can then Press 1 for more Information, which is then represented by a number on the keypad)įor all of these troubles, with the exception of #8, please call your security company as they will require service call to resolve.The Type of Trouble your system is experiencing will be represented by a number, either by a lit LED on the keypad or a digit represented on the LCD screen:.The indicated zone is reading a low battery condition and needs a replacement battery. Thereof, how do you clear the yellow light on a DSC alarm Press the 7 key and you will receive a number corresponding to the affected zone.
#YELLOW LIGHT ON DSC ALARM PANEL MANUAL#
#YELLOW LIGHT ON DSC ALARM PANEL HOW TO#
Here are step-by-step instructions on how to check and acknowledge a trouble on the keypad of a DSC Power Series Alarm Monitoring Panel on your DSC Power Series security alarm panel, and how to silence that beep: How to Acknowledge and Check a Trouble Condition DSC Power Series PC1616, PC1832 and PC1864 DSC Quick User Guide (PC1616/PC1832/PC1864) DSC7 DSC Alarm System (PC1616 / PC1832 / PC1864) Quick User Guide Arming & Disarming the System Arming (Turning on) Close all sensors (i.e. these should be need replaced every 3 - 5 years. press 2, see which LEDs light up- that will tell you what the trouble condition is (the LEDs for zones will light, or if its an LCD display something will show up there. If you receive a trouble condition on your alarm system, call our service department and we will help get the issue resolved. chances are this is a DSC power series panel used by ADT. This will illuminate a yellow triangle-shaped light on the keypad (as shown in in the picture) and start a beep, and will describe what the issue is. Trouble conditions are wide ranging and can be anything from a low battery to a power failure to a communications failure. From time to time, conditions may arise which cause what is known as a ‘trouble’ condition on the keypad. This tip is applicable if you use your system at home or for your business or commercial security alarm system.
![yellow light on dsc alarm panel yellow light on dsc alarm panel](https://www.home-security-systems-answers.com/images/burglar-alarm-system-troubleshooting-052.jpg)
In this tech tip, we’ll look at how to check and acknowledge a trouble on the keypad of a DSC Power Series Alarm Monitoring Panel. If you receive a trouble condition on your alarm system, call our service department and we will help get the issue resolved. In these regular posts, we’ll walk you through “How-To’s” for equipment that we service, and questions that we are regularly asked from you, our customers. This will illuminate a yellow triangle-shaped light on the keypad (as shown in in the picture) and start a beep, and will describe what the issue is.